The working principle of gas burner is introduced in detail
时间:2021-12-16 浏览次数: 1107 作者: 加科

   The working principle of gas burner is introduced in detail: circuit fault, unstable power supply or lack of phase, and flameout in the process of formation. Treatment method: Electrician shall check the power supply and wiring. Failure of gas boiler combustor not to start press the start button for a long time, the gas boiler combustor does not start the external interlocking failure, and the external temperature or pressure control does not reach the lower limit of start; Check the temperature or pressure setting.

   When the internal interlock of gas boiler burner fails to pass, the air pressure is too high or too low, the air pressure switch is normally closed, the air valve mechanism is not in place, it will appear, and the inspection will be carried out step by step. If the program controller fails to reset, reset it again. Civil gas boiler combustor, civil stove, lighter, blowtorch, spray combustion device in engine, etc. all belong to civil granular gas boiler combustor.

   The utility model relates to a civil infrared gas boiler combustor, which has a gas boiler combustion shell, a microporous ceramic inner fire plate, a microporous ceramic outer fire plate, an air inlet pipe and an air mixing chamber of the microporous ceramic inner fire plate, an air inlet pipe and an air mixing chamber of the microporous ceramic outer fire plate. The microporous ceramic outer fire plate is a ring fire plate, and its front and back ends are flush with the plate surface of the microporous ceramic inner fire plate and are limited and supported by the combustion shell of the gas boiler.

   An air inlet is arranged between the microporous ceramic inner fire plate and the microporous ceramic outer fire plate, which is characterized in that the plate surface between the front and back ends of the microporous ceramic outer fire plate is composed of a concave surface located in the outer ring of the plate surface and a convex surface located in the inner ring of the plate surface, The contour shape and size of the plate surface between the front and back ends of the microporous ceramic outer fire plate in any section passing through the rotation axis of the microporous ceramic inner fire plate are the same.


咨询热线
  • 座机:0531-83659330
  • 传真:0531-83382689
  • 邮箱:admin@gaco.cc
  • 总部地址:山东济南市章丘区宁石路9号
最新动态
加科与河南兰兴革业达成战略合作,助力皮革行业绿色升级
加科与河南兰兴革业达成战略合作,助力皮革行业绿色升级

近日,兰兴革业成功购入加科燃烧器的产品。此次合作旨在提升兰兴革业的生产效率,优化能源利用,同时进一步践行环保理···

+MORE
032025-06
安装落地:加科燃烧器为神马集团打造降本增效新引擎
安装落地:加科燃烧器为神马集团打造降本增效新引擎

近日,加科与神马集团在能源设备领域的合作取得重要进展。加科顺利完成了为神马集团安装两台油气两用燃烧器和一台燃气···

+MORE
012025-04
联系我们

24小时竭诚为您服务

15563365608(微信同号)

地址:山东省济南市章丘区宁石路9号

邮箱:admin@gaco.cc

电话
0531-83659330
微信
微信二位码
留言
返回顶部
加科(山东)智能装备有限公司 备案号:鲁ICP备17025986号-5
首页
产品
咨询
应用
服务